{"id":11057,"date":"2026-10-30T11:48:08","date_gmt":"2026-10-30T10:48:08","guid":{"rendered":"https:\/\/nexxusbio.com\/?p=11057"},"modified":"2026-10-30T11:48:08","modified_gmt":"2026-10-30T10:48:08","slug":"ako-citat-chromatogram-hplc","status":"publish","type":"post","link":"https:\/\/nexxusbio.com\/en\/ako-citat-chromatogram-hplc\/","title":{"rendered":"How to read the HPLC chromatogram and evaluate purity"},"content":{"rendered":"<p>Dva chromatogramy m\u00f4\u017eu na prv\u00fd poh\u013ead vyzera\u0165 rovnako \u010disto, no ich analytick\u00e1 v\u00fdpove\u010f m\u00f4\u017ee by\u0165 z\u00e1sadne odli\u0161n\u00e1. Rozhoduje nastavenie met\u00f3dy, typ detekcie, integr\u00e1cia p\u00edkov aj to, \u010di bol v\u00fdsledok priraden\u00fd ku konkr\u00e9tnemu \u010d\u00edslu \u0161ar\u017ee. Ot\u00e1zka, <strong>ako \u010d\u00edta\u0165 chromatogram HPLC<\/strong>, preto nie je len o n\u00e1jden\u00ed najvy\u0161\u0161ieho p\u00edku. Ide o pos\u00fadenie, \u010do dan\u00fd z\u00e1znam skuto\u010dne dokazuje a kde s\u00fa jeho hranice.<\/p>\n<p>Pri research-grade materi\u00e1loch je chromatogram HPLC \u010dasto <a href=\"https:\/\/nexxusbio.com\/en\/ako-citat-coa-peptidov\/\">s\u00fa\u010das\u0165ou COA<\/a>. Spolu s identifik\u00e1ciou materi\u00e1lu, deklarovanou \u010distotou, \u010d\u00edslom \u0161ar\u017ee, formou a podmienkami skladovania vytv\u00e1ra z\u00e1klad doh\u013eadate\u013enej analytickej dokument\u00e1cie. Samotn\u00fd obr\u00e1zok chromatogramu v\u0161ak nesta\u010d\u00ed \u010d\u00edta\u0165 izolovane.<\/p>\n<h2>\u010co chromatogram HPLC zobrazuje<\/h2>\n<p>HPLC, teda vysoko\u00fa\u010dinn\u00e1 kvapalinov\u00e1 chromatografia, odde\u013euje zlo\u017eky vzorky pod\u013ea ich interakcie so stacion\u00e1rnou a mobilnou f\u00e1zou. Detektor n\u00e1sledne zaznamen\u00e1 odozvu v \u010dase. V\u00fdsledkom je graf, kde vodorovn\u00e1 os obvykle predstavuje reten\u010dn\u00fd \u010das v min\u00fatach a zvisl\u00e1 os intenzitu detektorovej odozvy, napr\u00edklad absorbanciu pri ur\u010ditej vlnovej d\u013a\u017eke.<\/p>\n<p>Ka\u017ed\u00fd p\u00edk znamen\u00e1, \u017ee detektor v danom \u010dase zaznamenal eluuj\u00facu zlo\u017eku. Hlavn\u00fd p\u00edk sa pri spr\u00e1vne zvolenej met\u00f3de \u010dasto sp\u00e1ja s analyzovanou l\u00e1tkou. Men\u0161ie p\u00edky m\u00f4\u017eu predstavova\u0165 pr\u00edbuzn\u00e9 ne\u010distoty, ved\u013eaj\u0161ie produkty synt\u00e9zy, degrada\u010dn\u00e9 produkty, zlo\u017eky matrice alebo analytick\u00fd \u0161um. Ich p\u00f4vod nemo\u017eno ur\u010di\u0165 iba pod\u013ea v\u00fd\u0161ky p\u00edku.<\/p>\n<p>Chromatogram teda nie je priama fotografia chemick\u00e9ho zlo\u017eenia. Je to v\u00fdsledok konkr\u00e9tneho separa\u010dn\u00e9ho syst\u00e9mu, detektora, spracovania d\u00e1t a podmienok merania. T\u00e1to okolnos\u0165 je rozhoduj\u00faca najm\u00e4 pri porovn\u00e1van\u00ed dokument\u00e1cie od r\u00f4znych laborat\u00f3ri\u00ed alebo medzi r\u00f4znymi \u0161ar\u017eami materi\u00e1lu.<\/p>\n<h2>Ako \u010d\u00edta\u0165 chromatogram HPLC krok za krokom<\/h2>\n<h3>1. Overte identifik\u00e1ciu vzorky a \u0161ar\u017ee<\/h3>\n<p>Najprv skontrolujte, \u010di chromatogram patr\u00ed presne k hodnoten\u00e9mu materi\u00e1lu. COA by malo uv\u00e1dza\u0165 n\u00e1zov alebo ozna\u010denie analyzovanej l\u00e1tky, \u010d\u00edslo \u0161ar\u017ee, d\u00e1tum anal\u00fdzy a ide\u00e1lne aj intern\u00e9 ozna\u010denie vzorky. Ak je chromatogram v\u0161eobecn\u00fd, bez v\u00e4zby na konkr\u00e9tnu \u0161ar\u017eu, m\u00e1 obmedzen\u00fa hodnotu pre pos\u00fadenie aktu\u00e1lne dodan\u00e9ho materi\u00e1lu.<\/p>\n<p>Doh\u013eadate\u013enos\u0165 je praktick\u00e1 aj pri neskor\u0161om porovnan\u00ed v\u00fdsledkov. Pri anal\u00fdze inej \u0161ar\u017ee m\u00f4\u017ee by\u0165 reten\u010dn\u00fd \u010das podobn\u00fd, ale plocha ved\u013eaj\u0161\u00edch p\u00edkov, priebeh z\u00e1kladnej l\u00ednie alebo celkov\u00e1 deklarovan\u00e1 \u010distota sa m\u00f4\u017eu meni\u0165. Tak\u00e1to zmena nie je automaticky zn\u00e1mkou nevyhovuj\u00faceho materi\u00e1lu, ale vy\u017eaduje kontext met\u00f3dy a \u0161pecifik\u00e1cie.<\/p>\n<h3>2. N\u00e1jdite reten\u010dn\u00fd \u010das hlavn\u00e9ho p\u00edku<\/h3>\n<p>Reten\u010dn\u00fd \u010das je \u010das, za ktor\u00fd zlo\u017eka prejde chromatografick\u00fdm syst\u00e9mom k detektoru. V tabu\u013eke pri chromatograme b\u00fdva ozna\u010den\u00fd ako RT alebo retention time. Hlavn\u00fd p\u00edk m\u00e1 ma\u0165 reten\u010dn\u00fd \u010das, ktor\u00fd zodpoved\u00e1 o\u010dak\u00e1vaniu pre dan\u00fa met\u00f3du a referen\u010dn\u00fd \u0161tandard, ak bol pou\u017eit\u00fd.<\/p>\n<p>Reten\u010dn\u00fd \u010das s\u00e1m osebe nepotvrdzuje identitu s absol\u00fatnou istotou. Dve rozdielne l\u00e1tky m\u00f4\u017eu za ur\u010dit\u00fdch podmienok eluova\u0165 ve\u013emi bl\u00edzko pri sebe. Preto sa pri d\u00f4slednej analytickej charakteriz\u00e1cii identita posudzuje kombin\u00e1ciou \u00fadajov, napr\u00edklad porovnan\u00edm s referen\u010dn\u00fdm \u0161tandardom, LC-MS v\u00fdsledkom alebo \u010fal\u0161ou ortogon\u00e1lnou analytickou technikou.<\/p>\n<p>Mal\u00fd posun reten\u010dn\u00e9ho \u010dasu medzi anal\u00fdzami nemus\u00ed znamena\u0165 zmenu materi\u00e1lu. Ovplyvni\u0165 ho m\u00f4\u017ee stav kol\u00f3ny, teplota, zlo\u017eenie mobilnej f\u00e1zy, prietok alebo rozdiel medzi pr\u00edstrojmi. Relevantn\u00e9 je, \u010di je posun v medziach akceptovan\u00fdch pre konkr\u00e9tnu met\u00f3du.<\/p>\n<h3>3. Rozli\u0161ujte v\u00fd\u0161ku, plochu a tvar p\u00edku<\/h3>\n<p>V\u00fd\u0161ka p\u00edku ukazuje maxim\u00e1lnu odozvu detektora, ale pri hodnoten\u00ed relat\u00edvneho zast\u00fapenia zlo\u017eiek sa \u010dastej\u0161ie pou\u017e\u00edva plocha p\u00edku. Ak COA uv\u00e1dza \u010distotu napr\u00edklad ako 98 %, zvy\u010dajne ide o percentu\u00e1lny podiel plochy hlavn\u00e9ho p\u00edku na s\u00fa\u010dte integrovan\u00fdch pl\u00f4ch relevantn\u00fdch p\u00edkov.<\/p>\n<p>To v\u0161ak neznamen\u00e1, \u017ee 98 % plochy automaticky predstavuje 98 % hmotnostn\u00fa \u010distotu. Pri UV detekcii maj\u00fa r\u00f4zne molekuly rozdielnu odozvu v z\u00e1vislosti od svojej \u0161trukt\u00fary a pou\u017eitej vlnovej d\u013a\u017eky. Ne\u010distota s ni\u017e\u0161ou alebo vy\u0161\u0161ou UV odozvou m\u00f4\u017ee by\u0165 v skuto\u010dnosti zast\u00fapen\u00e1 inak, ne\u017e nazna\u010duje jej relat\u00edvna plocha. Ozna\u010denie \u201eHPLC purity by area percent\u201c je preto potrebn\u00e9 ch\u00e1pa\u0165 presne ako chromatografick\u00fa, nie univerz\u00e1lnu hmotnostn\u00fa hodnotu.<\/p>\n<p>Tvar hlavn\u00e9ho p\u00edku poskytuje \u010fal\u0161iu inform\u00e1ciu. Symetrick\u00fd a dobre oddelen\u00fd p\u00edk sa vyhodnocuje spo\u013eahlivej\u0161ie ne\u017e \u0161irok\u00fd, asymetrick\u00fd alebo prekr\u00fdvaj\u00faci sa p\u00edk. Tailing, teda pred\u013a\u017een\u00e9 klesanie p\u00edku, m\u00f4\u017ee s\u00favisie\u0165 s interakciami na kol\u00f3ne, pre\u0165a\u017een\u00edm alebo vlastnos\u0165ami analyzovanej l\u00e1tky. Fronting m\u00f4\u017ee poukazova\u0165 napr\u00edklad na nevhodn\u00e9 mno\u017estvo vzorky alebo probl\u00e9m so separ\u00e1ciou. Bez \u00fadajov o met\u00f3de v\u0161ak nemo\u017eno z tvaru p\u00edku vyvodzova\u0165 jednozna\u010dn\u00fd z\u00e1ver o kvalite materi\u00e1lu.<\/p>\n<h3>4. Skontrolujte mal\u00e9 p\u00edky a rozl\u00ed\u0161enie separ\u00e1cie<\/h3>\n<p>Ved\u013eaj\u0161ie p\u00edky pri hlavnom p\u00edku si zasl\u00fa\u017eia pozornos\u0165 najm\u00e4 vtedy, ak nie s\u00fa od neho jasne oddelen\u00e9. Ak dva p\u00edky spl\u00fdvaj\u00fa, integr\u00e1cia ich pl\u00f4ch m\u00f4\u017ee by\u0165 neist\u00e1 a hodnota \u010distoty nemus\u00ed presne odr\u00e1\u017ea\u0165 podiel jednotliv\u00fdch zlo\u017eiek. V ide\u00e1lnom pr\u00edpade chromatogram ukazuje dostato\u010dn\u00e9 rozl\u00ed\u0161enie medzi hlavn\u00fdm p\u00edkom a susedn\u00fdmi p\u00edkmi.<\/p>\n<p>Nie ka\u017ed\u00fd mal\u00fd sign\u00e1l je ne\u010distota materi\u00e1lu. Sign\u00e1ly na za\u010diatku behu m\u00f4\u017eu poch\u00e1dza\u0165 z rozp\u00fa\u0161\u0165adla, syst\u00e9mu alebo injek\u010dn\u00e9ho procesu. Naopak, mal\u00e9 ale konzistentn\u00e9 p\u00edky v oblasti relevantnej retencie m\u00f4\u017eu by\u0165 analyticky v\u00fdznamn\u00e9. Posudzova\u0165 ich treba pod\u013ea integra\u010dnej tabu\u013eky, limitov met\u00f3dy a zn\u00e1mych vlastnost\u00ed analyzovan\u00e9ho materi\u00e1lu.<\/p>\n<h3>5. Pozrite sa na z\u00e1kladn\u00fa l\u00edniu<\/h3>\n<p>Z\u00e1kladn\u00e1 l\u00ednia, \u010dasto ozna\u010dovan\u00e1 ako baseline, by mala by\u0165 primerane stabiln\u00e1. Jej kol\u00edsanie, drift alebo v\u00fdrazn\u00e9 ru\u0161enie m\u00f4\u017ee komplikova\u0165 spo\u013eahliv\u00fa integr\u00e1ciu mal\u00fdch p\u00edkov. Pr\u00ed\u010dinou m\u00f4\u017eu by\u0165 zmeny v mobilnej f\u00e1ze, teplote, stave kol\u00f3ny, kontamin\u00e1cia syst\u00e9mu alebo vlastnosti detektora.<\/p>\n<p>Mierny drift s\u00e1m osebe nemus\u00ed znehodnoti\u0165 v\u00fdsledok, najm\u00e4 pri dlh\u0161\u00edch gradientoch. Ak v\u0161ak z\u00e1kladn\u00e1 l\u00ednia v\u00fdrazne nar\u00fa\u0161a oblas\u0165 hlavn\u00e9ho p\u00edku alebo oblasti mal\u00fdch p\u00edkov, analytick\u00fd v\u00fdstup treba interpretova\u0165 opatrne. Pri dokument\u00e1cii je vhodn\u00e9, aby bolo vidite\u013en\u00e9 cel\u00e9 relevantn\u00e9 \u010dasov\u00e9 okno, nie len orezan\u00e1 oblas\u0165 hlavn\u00e9ho p\u00edku.<\/p>\n<h2>\u010cistota z HPLC nie je \u00fapln\u00e1 identita materi\u00e1lu<\/h2>\n<p>HPLC je vhodn\u00fd n\u00e1stroj na pos\u00fadenie chromatografickej \u010distoty a na sledovanie pr\u00edbuzn\u00fdch zlo\u017eiek v r\u00e1mci validovan\u00e9ho alebo \u00fa\u010delovo nastaven\u00e9ho postupu. Neodpoved\u00e1 v\u0161ak na v\u0161etky ot\u00e1zky o materi\u00e1li. Samotn\u00fd chromatogram napr\u00edklad nemus\u00ed spo\u013eahlivo odhali\u0165 ka\u017ed\u00fa ne-UV akt\u00edvnu ne\u010distotu, anorganick\u00e9 zvy\u0161ky, rezidu\u00e1lne rozp\u00fa\u0161\u0165adl\u00e1 alebo \u0161truktur\u00e1lne podobn\u00e9 l\u00e1tky, ktor\u00e9 sa za dan\u00fdch podmienok nedostato\u010dne separuj\u00fa.<\/p>\n<p>Preto m\u00e1 pri analytickej charakteriz\u00e1cii v\u00fdznam kombin\u00e1cia techn\u00edk. LC-MS m\u00f4\u017ee podpori\u0165 potvrdenie molekulovej hmotnosti a pr\u00edtomnosti o\u010dak\u00e1van\u00e9ho i\u00f3nu. Pri niektor\u00fdch materi\u00e1loch m\u00f4\u017eu by\u0165 relevantn\u00e9 aj \u00fadaje o obsahu vody, zvy\u0161koch rozp\u00fa\u0161\u0165adiel, obsahu protii\u00f3nu alebo mikrobiologick\u00fdch parametroch, pod\u013ea povahy materi\u00e1lu a zam\u00fd\u0161\u013ean\u00e9ho laborat\u00f3rneho pou\u017eitia. Rozsah potrebnej dokument\u00e1cie v\u017edy z\u00e1vis\u00ed od typu vzorky a po\u017eiadaviek konkr\u00e9tneho v\u00fdskumn\u00e9ho pracoviska.<\/p>\n<h2>Ako porovn\u00e1va\u0165 HPLC chromatogram s COA<\/h2>\n<p>D\u00f4veryhodn\u00e9 COA prep\u00e1ja chromatogram s konkr\u00e9tnymi \u00fadajmi. Pri kontrole dokument\u00e1cie m\u00e1 zmysel porovna\u0165 n\u00e1zov materi\u00e1lu, \u010d\u00edslo \u0161ar\u017ee, deklarovan\u00fa \u010distotu, reten\u010dn\u00fd \u010das, detek\u010dn\u00fa vlnov\u00fa d\u013a\u017eku a d\u00e1tum anal\u00fdzy. U\u017eito\u010dn\u00e9 je aj uvedenie typu kol\u00f3ny, mobilnej f\u00e1zy alebo gradientu, hoci rozsah zverejnen\u00fdch \u00fadajov m\u00f4\u017ee by\u0165 odli\u0161n\u00fd pod\u013ea laborat\u00f3ria.<\/p>\n<p>Ak COA uv\u00e1dza iba <a href=\"https:\/\/nexxusbio.com\/en\/cistota-peptidov-nad-99-co-znamena\/\">jednu hodnotu \u010distoty<\/a> bez chromatogramu, bez \u0161ar\u017ee alebo bez analytick\u00e9ho kontextu, \u010ditate\u013e nem\u00e1 dostatok podkladov na samostatn\u00e9 pos\u00fadenie v\u00fdsledku. Na druhej strane ani detailn\u00fd chromatogram nenahr\u00e1dza spr\u00e1vne ozna\u010denie obalu, konzistentn\u00e9 skladovacie podmienky a doh\u013eadate\u013enos\u0165 v dod\u00e1vate\u013eskom re\u0165azci.<\/p>\n<p>Pri porovnan\u00ed dvoch COA sa nes\u00fastre\u010fte iba na vy\u0161\u0161ie percento. \u010cistota 99 % z\u00edskan\u00e1 pri jednej UV vlnovej d\u013a\u017eke a konkr\u00e9tnej integra\u010dnej met\u00f3de nemus\u00ed by\u0165 priamo porovnate\u013en\u00e1 s hodnotou 98 % z in\u00e9ho syst\u00e9mu. V\u00e4\u010d\u0161iu v\u00fdpovedn\u00fa hodnotu m\u00e1 <a href=\"https:\/\/nexxusbio.com\/en\/ako-porovnat-kvalitu-peptidov\/\">s\u00fabor konzistentn\u00fdch \u00fadajov<\/a>: jasn\u00e1 v\u00e4zba na \u0161ar\u017eu, \u010ditate\u013en\u00fd chromatogram, zrozumite\u013en\u00e1 analytick\u00e1 met\u00f3da a primeran\u00e1 doplnkov\u00e1 identifik\u00e1cia.<\/p>\n<h2>Naj\u010dastej\u0161ie chyby pri interpret\u00e1cii<\/h2>\n<p>Prvou chybou je stoto\u017enenie najv\u00e4\u010d\u0161ieho p\u00edku s potvrdenou identitou. Hlavn\u00fd p\u00edk m\u00f4\u017ee by\u0165 dobr\u00fdm indik\u00e1torom, ale bez referen\u010dn\u00e9ho porovnania alebo doplnkovej anal\u00fdzy nepredstavuje \u00fapln\u00fd d\u00f4kaz identity. Druhou chybou je ch\u00e1pa\u0165 percento plochy ako univerz\u00e1lne percento chemickej \u010distoty bez oh\u013eadu na detektor a odozvov\u00e9 faktory.<\/p>\n<p>Tre\u0165ou chybou je ignorovanie integra\u010dn\u00fdch hran\u00edc. Softv\u00e9r rozhoduje o tom, kde p\u00edk za\u010d\u00edna a kon\u010d\u00ed, pod\u013ea nastaven\u00fdch pravidiel. Odli\u0161n\u00e9 nastavenie baseline, prahu alebo sp\u00f4sobu delenia prekr\u00fdvaj\u00facich sa p\u00edkov m\u00f4\u017ee zmeni\u0165 vypo\u010d\u00edtan\u00fa relat\u00edvnu \u010distotu. Pri kvalitnom analytickom syst\u00e9me musia by\u0165 tieto pravidl\u00e1 kontrolovan\u00e9 a konzistentn\u00e9.<\/p>\n<p>Napokon, chromatogram nehodno\u0165te bez inform\u00e1cie o \u010dase a skladovan\u00ed vzorky. Niektor\u00e9 materi\u00e1ly m\u00f4\u017eu by\u0165 citliv\u00e9 na vlhkos\u0165, svetlo, teplotu alebo opakovan\u00fa manipul\u00e1ciu. Dokument\u00e1cia \u0161ar\u017ee popisuje stav analyzovanej vzorky v \u010dase merania, nie nevyhnutne stav ka\u017edej vzorky po odli\u0161nom skladovan\u00ed.<\/p>\n<h2>Praktick\u00fd r\u00e1mec pre \u010d\u00edtanie chromatogramu HPLC<\/h2>\n<p>Pri r\u00fdchlom hodnoten\u00ed si polo\u017ete nieko\u013eko ot\u00e1zok. Je chromatogram priraden\u00fd k spr\u00e1vnemu \u010d\u00edslu \u0161ar\u017ee? Je hlavn\u00fd p\u00edk jasne ozna\u010den\u00fd a primerane oddelen\u00fd? Zodpoved\u00e1 deklarovan\u00e1 \u010distota integra\u010dnej tabu\u013eke? Je zrejm\u00e9, ak\u00fd detektor a ak\u00e1 vlnov\u00e1 d\u013a\u017eka boli pou\u017eit\u00e9? A existuje doplnkov\u00fd \u00fadaj, ktor\u00fd podporuje identitu materi\u00e1lu?<\/p>\n<p>Ak na niektor\u00fa z t\u00fdchto ot\u00e1zok dokument\u00e1cia neodpoved\u00e1, nejde automaticky o negat\u00edvne zistenie. Znamen\u00e1 to v\u0161ak, \u017ee analytick\u00fd z\u00e1ver m\u00e1 by\u0165 u\u017e\u0161\u00ed a \u017ee pri v\u00fdbere research-grade materi\u00e1lu treba zoh\u013eadni\u0165 rozsah dostupn\u00fdch d\u00e1t. Transparentn\u00e1 dokument\u00e1cia umo\u017e\u0148uje porovn\u00e1va\u0165 materi\u00e1ly na z\u00e1klade overite\u013en\u00fdch \u00fadajov, nie iba na z\u00e1klade deklarovan\u00e9ho percenta \u010distoty.<\/p>\n<h3>Warning<\/h3>\n<p>The content is intended for informational and professional purposes in a scientific and laboratory context only. It is not intended as a guide for human or veterinary use, diagnosis, prevention, or treatment.<\/p>","protected":false},"excerpt":{"rendered":"<p>Ako \u010d\u00edta\u0165 chromatogram HPLC: vysvetlenie reten\u010dn\u00e9ho \u010dasu, pl\u00f4ch p\u00edkov, \u010distoty, baseline a obmedzen\u00ed pri hodnoten\u00ed COA a \u0161ar\u017ee materi\u00e1lu v laborat\u00f3riu.<\/p>","protected":false},"author":2,"featured_media":11058,"comment_status":"closed","ping_status":"","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[194],"tags":[],"class_list":["post-11057","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vyskum-peptidov"],"_links":{"self":[{"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/posts\/11057","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/comments?post=11057"}],"version-history":[{"count":1,"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/posts\/11057\/revisions"}],"predecessor-version":[{"id":11278,"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/posts\/11057\/revisions\/11278"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/media\/11058"}],"wp:attachment":[{"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/media?parent=11057"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/categories?post=11057"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nexxusbio.com\/en\/wp-json\/wp\/v2\/tags?post=11057"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}